'Doomaz' <Doo..@doomaz.com> wrote in message
news:aAZNa.35800$n%5.7283@nwrddc02.gnilink.net..

When you are starting the genset, it is running from battery
power, ignoring the low oil pressure switch, and ignoring any
'stop' signal whether from local or remote switch. To switch to
'run' mode and stay running, it -must- be generating somewhere
close to the correct voltage, must have oil pressure, and
must -not- have a stop signal from local or remote switch.
As a first step, unplug the remote connector (right side of
genset control box) and try starting with the switch on the
genset - if it stays running, you have a problem with the remote
switch or wiring.
If that doesn't do it, you need to hook up a voltmeter to the
output of the genset and see what voltage it actually -is-
putting out. If the voltage is (approx 45v) and the set is one of
the early transformer-regulated Emeralds (spec A-C), you may have
blown the diode bridge in the control box. If the Emerald is a
later (electronic regulator) spec, you -may- have blown the
regulator. This is usually caused by tarnish buildup on the slip
rings causing high resistance in the field circuit - remove the
cover in the genset housing behind the air cleaner to expose the
brush holder and measure resistance from one brush lead to the
other - should be approx 25 ohms - much more than 35 ohms is a
potential problem, and will require cleaning the slip rings and
brush tips. If it's an electronic regulator set and you're -very-
lucky, the regulator may have survived and cleaning the slip
rings/brushes -may- be all that's needed.
If the output voltage of the genset is approx 120v and it won't
stay running, you may have a control board problem rather than a
voltage regulator problem.
I'll be glad to furnish detailed troubleshooting directions, but
I need to know the full model/spec of your genset (should be on
the fan housing, something like 4.0BGE-1R/26100F or similar).

Onan Microquiet 4000 Generator Owners Manual

Electric Fuel Pump Replaces for Airtex E11007 A029F889 149-2311 149-2311-02 149-2331101,Fit for Onan Cummins Generator 4KW Microlite MicroQuiet 4000 4Kw RV 4.5 out of 5 stars 546 $24.99 $ 24. From the Onan nameplate. For handy reference, insert your nameplate infor- mation in the spaces below. MODEL AND SPEC NO. DIGITAL CONTROL SOFTWARE VERSION AND DATE (IF APPLICABLE) SAFETY PRECAUTIONS The following symbols are used in Onan manuals to alert users to the potentially dangerous condi. The Onan 4000 Generator Expectations - RV Generators Online Onan 4K MicroQuiet Generator Maintenance - RV Road Trip RV Generator Manuals Cummins Inc. Onan MicroLite 4000 Series Manuals ManualsLib ONAN – Service Manual Download Amazon.com: onan microquiet 4000 parts Onan 4000 Microlite Wiring Diagram Onan MicroQuiet 4000 generator. Onan microquiet 4000 owners manual Media Publishing eBook, ePub, Kindle PDF View ID a34080c43 May 12, 2020 By Enid Blyton service a041d133 to easily locate the nearest cummins onan may 10 2020 by eleanor hibbert read onan. Onan 4000-Watt RV Generators—Buy Direct & Save—Free Shipping—Ships in 1 - 2 Days—runs 1 A/C unit + power for lights, appliances.